CRITICAL · CVSS 9.8
EPSS exploitation probability: 0%
Published 2018-06-26T20:29:00.227 · Last modified 2026-06-17T01:34:14.343

Summary

Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Affected products

deltaww — commgr

Does this affect you?

Add your gear to cvedb and we'll alert you only when deltaww ships something exploited.