The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
Add your gear to cvedb and we'll alert you only when a vendor you run ships something exploited.
Check my exposure →This product uses data from the NVD API but is not endorsed or certified by the NVD. Informational only; not professional security advice.